Samsung DVM S - HEAT RECOVERY UNIT ERV

Unidade de recuperação de calor

Download BIM/CAD
AutoCAD
3
Revit
3
Solicite um arquivo BIM / CAD

Product
Samsung / DVM S - HEAT RECOVERY UNIT ERV / Unidade de recuperação de calor

ADD TO WISHLIST OR PROJECT
Resumo
Coleção
Nome produto/artigo

DVM S - HEAT RECOVERY UNIT ERV

Tipo

Unidade de recuperação de calor

• 2 fans, centrifugal type with directly connected to inverter electric motor.‎
• Operating mode: heat recovery / Free cooling (ventilation only) / AUTO.‎
• Filter with class equivalent to F7 with antibacterial treatment.‎
• Power supply 220-240V, single-phase + neutral – 50 Hz

Product codes:
AN026JSKLKN/EU
AN035JSKLKN/EU
AN050JSKLKN/EU
AN080JSKLKN/EU
AN100JSKLKN/EU

The variable flow system DVM (Digital variable Multi) by Samsung allows, thanks to the exclusive use of the dual inverter compressor (produced by Samsung), a high efficiency at
partial loads and a quick start-up in heating/cooling, while Flash injection technology guarantees high performance especially at low temperatures.‎
The variable flow of refrigerant technology optimizes the consumption of electricity as it is able to vary the power supplied according to the thermal demand in the rooms to be air conditioned.‎
The cycle efficiency with Inverter scroll compressor and Flash injection technology is superior to that of a traditional compressor, as the additional capacity resulting from undercooling is obtained with less power absorbed: the steam, produced in the undercooling process, is compressed only from an intermediate pressure (higher than the intake pressure) thus ensuring greater efficiency.‎
The Flash injection technology then injects two-phase refrigerant (gas and liquid) at medium pressure inside the compressor spirals so as to obtain two compression stages with better efficiency and high performance at low temperature.‎
The brazed plate exchanger inside the outdoor unit used for undercooling increases the exchange efficiency by 30% compared to the classic Shell&Tube models and by 50% compared to the double tube models.‎
Each DVM S outdoor unit has 1-2 Samsung Inverter compressors, all equipped with Flash injection technology.‎
The DVM system allows a quick and simple installation, as the connection between the indoor units and the outdoor units is made through the use of two copper pipes, in which the refrigerant fluid R410A circulates.‎
The operating limits are very high: 48°C in cooling and -25°C in heating, to ensure a high level of comfort and efficiency throughout the year.‎
The DVM S HR allows connected indoor units to operate in heating or cooling mode simultaneously (thanks to the heat recovery that ensures a high energy saving) to satisfy the various installation requirements or the different exposures to irradiation.‎
The correct flow of refrigerant inside the evaporator is regulated by an electronic expansion valve (EEV) to 2000 step which is able to vary instantly, thanks to the continuous dialogue between the internal and external PCB, the passage of the refrigerant.‎

Dimensões
AN026JSKLKN/EU: 600 x 350 x 660 mm
AN035JSKLKN/EU: 1012 x 270 x 1000 mm
AN050JSKLKN/EU: 1012 x 270 x 1000 mm
AN080JSKLKN/EU: 1220 x 340 x 1135 mm
AN100JSKLKN/EU: 1220 x 340 x 1135 mm
Bim e Cad
AutoCAD
Revit

Coleção DVM S por Samsung
Poderá também gostar de
Produtos vistos recentemente
Download BIM/CAD
AutoCAD
3
[DWG] ERV 026
[DWG] ERV 080 100
[DWG] ERV 035 050
Download BIM/CAD
Revit
3
SAMSUNG ERV 80 100
SAMSUNG ERV 35 50
SAMSUNG ERV 26

Salvar em:

Conferma la tua posizione

per scoprire le offerte valide nella tua zona

CAP
OK
Usa la mia posizione
Salvar em: